View Single Post
  #16   Report Post  
Old January 23rd 19, 08:11 AM posted to uk.railway,uk.transport.london
Anna Noyd-Dryver Anna Noyd-Dryver is offline
external usenet poster
 
First recorded activity at LondonBanter: Jan 2015
Posts: 355
Default When the software meets the hardware

Recliner wrote:

From Roger Ford's 'Informed Sources' e-preview:

Quote:

Engineers commissioning the new generation of software-enabled trains are
facing the problem that pretty well every system, and even sub-system, on
their train is computer controlled with its own software. This also has to
interface with the train’s third party software based systems.

For example, during a recent run in a Great Western Railway Class 800 the
Universal Access Toilet was all lit up, but the door had lost power and
wouldn’t lock. When I reported this failure to a member of the on-board
staff, she replied that it was a common issue and the toilet needed
re-booting.


IMX the two usual problems with the UAT are door and water.

The door has two main problems, both arising when it’s not left to 'do its
own thing'. The main one is that after unlocking the door, it seems to take
about 1/2 second for the door open button to become responsive. Press it
too quick and the door doesn’t open despite the button being illuminated.
People then push the door manually to open it and the toilet declares
itself out of use because it thinks the door is broken. Solution - push it
closed and it’s happy again. The second door problem is similar - sometimes
a cant, or an over-enthusiastic door mech, makes the door bounce back
slightly off the frame - only a centimetre or so, but enough that the
toilet declares itself OOU. The solution is the same as before.

Water pressure (distinct from water level or waste tank level) seems to be
a recurring problem across the fleet - I’ve taken a 9-car from Stoke
Gifford to Swindon empty and by the time I got to Swindon 5 toilets had
declared themselves failed! This is the failure which results in either
empty pan (rather than the usual couple of inches of water in the bottom)
or, if used, full pan (not flushing). The UATs lock themselves out of use
in this situation, something the regular toilets can’t do. This fault can
sometimes, but rarely IMX, be solved by pressing the ‘reset’ button behind
the mirror.

The other annoying thing will the UAT module is that the tap sensor is
offset some way to the left of both the water outlet and the symbol above
it.


Anna Noyd-Dryver