Angus Bryant wrote:

"Boltar" wrote in message
om...

ITYF that the noise is more pronounced on older three phase designs.
Current production uses a later three-phase technology which has a less
pronounced "gear change" effect.


The older AC drives used GTO thyristors which operated at a frequency
the human ear can hear and because they had a max operating frequency
some sort of electronic equivalent of gear changing had to occur to let
them drived the motors at the full range of speeds required (don't know
the details I'm not an electronic engineer). The newer drives use IGB
transisters which operate at a much higher frequency though if the new
stock on the northern line is anything to go by you can still hear a
very high pitched whine.


I've noticed the sound produced by by the 3 phase drives of some GTO
powered trains can be heard on an AM radio. Perhaps someone here might
like to take a Walkman on one of these buses, to see if you get the same
effect.

Yep, that's just about right.

The gear changing is required because it's easier and more desirable [1] to
keep a fixed ratio of device (i.e. GTO) switching frequency to modulation
frequency (the latter is roughly proportional to the motor speed), and you
have a maximum limit on the GTO switching frequency [2].

From start-up you clearly need a high frequency ratio as the motor speed -
hence modulation frequency - is very small. Since GTOs cannot switch at
high speeds (well they can but you need snubbers to slow them down to stop
them blowing up) you cannot maintain a high frequency ratio as the motor
speed increases beyond a certain point, so when the maximum switching speed
has been reached the ratio steps down to the next suitable value. The
modulation frequency remains the same, since the motor speed is the same,
but the switching frequency has been reduced. It is the switching frequency
which you can hear changing through the motor. This process happens many
times as the motor speed increases.


What are snubbers?

IGBTs can switch more quickly as they don't generally need snubbering, and
hence a higher switching frequency is used. It's just about audible (as
Boltar said, I think it may be the whine you hear on the Northern Line). As
the switching frequency is higher, the ratio of switching to modulation
frequency is greater and can be non-integer. The switching frequency is
therefore fixed, and so you don't hear the gear-changing.

[1] If this ratio is less than approx. 21 and not an odd integer then
subharmonics are a problem. Above approx. 21 it's less of a problem and
non-integer values can be used.

[2] Just to clarify, the devices - whether IGBTs or GTOs - switch to form a
high-frequency square wave. The duty ratio of this square wave is ratio of
the time it spends on to the total period, so if the duty ratio is 1/3, it
spends 1/3 of the period on and 2/3 off. The duty ratio is varied over many
switching cycles to follow a sinewave (in classic examples). However the
motor is inductive, and this has the effect of filtering out the switching
and producing a current proportional to the *average* of the square wave.
This average is proportional to the duty ratio. Hence if the duty ratio
varies as a sinewave, the current will also be approx. sinusoidal. In an
induction motor we need a variable-voltage, variable-frequency sinewave on
each phase. Varying the duty ratio amplitude and frequency (=modulation
frequency) has this effect. The advantage of using pulse-width modulation
(PWM) switching to achieve this is that the switching process is very (90%)
efficient, since the devices only pass high currents at high voltages (hence
burn lots of power) when switching. You could use a linear amplifier (i.e.
a scaled-up audio amplifier) but its efficiency is rarely above 50%, which
is clearly a no-brainer.

Why do you need a sinewave - what's wrong with a VVVF squarewave?
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
free free 100 dollors free 4days only FRee REGISTER ONLy fffghgfghghhhj London Transport 0 June 23rd 08 04:29 AM
Win a Free gaming console, PS3, X-BOX or Nintendo wii, Free Prize Draw Michael London Transport 0 April 1st 07 05:37 PM
Win a Free gaming console, PS3, X-BOX or Nintendo wii, Free Prize Draw Michael London Transport 0 April 1st 07 05:36 PM
Scrutiny of Low Emission Zone plans TravelBot London Transport News 0 March 12th 06 07:45 PM
Consultation begins on Low Emission Zone proposal TravelBot London Transport News 0 March 12th 06 07:44 PM


All times are GMT. The time now is 07:39 AM.

Powered by vBulletin®
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 London Banter.
The comments are property of their posters.
 

About Us

"It's about London Transport"

 

Copyright © 2017