Many years ago, when telephone lines were in
very short supply, 'party lines' were common.
A party line, officially known as 'shared service',
meant 2 premises sharing the same pair of wires.

Incoming calls to one or the other were separated
by arranging the 75 volt AC bell ringing current to
travel out via one or other of the pair of wires and
return to the exchange via 'earth'. This required
driving a metal spike into the ground and connecting
the bell's return path via 3-strand bare copper wire.

One day I was called to a farm which had reported
their dog howling in distress every time the phone
rang. We sometimes had a laugh at the wording of
some customer's reports but I went down to the farm
all the same. I asked the operator to ring me back
and sure enough, the dog gave first a little yelp and
then a painful howl. After a few trials I went out into
the yard to see the dog repeating the cycle, peeing
as it did so. This couldn't be a coincidence, nor was it.

The farmer had secured his dog with a new steel chain
fastened by an eyebolt to a flat steel bar spiked into the
farmhouse wall. In doing so he had broken the earth
wire for the telephone. Instead of the ringing current
going to earth via the spike it was travelling through
the chain and the dog. The tickling of the 16.333 cycle
75V AC made the dog pee and gave the return ringing
current an even lower resistance path to earth via its
bladder and its willie.

Given such circumstances, wouldn't we all howl? ;-)


Regards,

DigitisED (Eddie Bellass)

Eddie & Margaret Bellass,
Merseyside, United Kingdom.

Outgoing mail is certified Virus Free and checked
by a leading anti-virus system - updated continuously.



  #2   Report Post  
Old July 22nd 08, 08:27 PM posted to uk.railway,uk.transport.london
external usenet poster
 
First recorded activity at LondonBanter: Sep 2004
Posts: 724
Default Man electrocuted after urinating on track

On Tue, 22 Jul 2008 19:24:34 GMT, "Eddie Bellass"
wrote:

Many years ago, when telephone lines were in
very short supply, 'party lines' were common.
A party line, officially known as 'shared service',
meant 2 premises sharing the same pair of wires.

Incoming calls to one or the other were separated
by arranging the 75 volt AC bell ringing current to
travel out via one or other of the pair of wires and
return to the exchange via 'earth'. This required
driving a metal spike into the ground and connecting
the bell's return path via 3-strand bare copper wire.

One day I was called to a farm which had reported
their dog howling in distress every time the phone
rang. We sometimes had a laugh at the wording of
some customer's reports but I went down to the farm
all the same. I asked the operator to ring me back
and sure enough, the dog gave first a little yelp and
then a painful howl. After a few trials I went out into
the yard to see the dog repeating the cycle, peeing
as it did so. This couldn't be a coincidence, nor was it.

The farmer had secured his dog with a new steel chain
fastened by an eyebolt to a flat steel bar spiked into the
farmhouse wall. In doing so he had broken the earth
wire for the telephone. Instead of the ringing current
going to earth via the spike it was travelling through
the chain and the dog. The tickling of the 16.333 cycle
75V AC made the dog pee and gave the return ringing
current an even lower resistance path to earth via its
bladder and its willie.

Given such circumstances, wouldn't we all howl? ;-)

Not so painful, but one day while I was doing my apprenticeship with
PO telephones, we received a "Fault for Special Investigation" form
for the local hairdressers. This was another installation using
earthed ringing (plan 107 = 1 main telephone plus 1 switched extension
at a different address) and the complaint was that it didn't work on
Monday and Friday mornings. We turned up on one of the appropriate
mornings and lo and behold it didn't work. Upon pulling out a few
hardboard panels to trace the earth connection we found that the earth
wire didn't go to any kind of proper earth connection but disappeared
down the shop's drain which on the day following the weekend or early
closing was dry and totally useless as a conductor.

"Older viewers" might remember manual telephones. One of the early
systems (Central Battery Signalling system No1 aka CBS1) also used an
earthed bell circuit (the "clear" signal was given by earthing one
side of the line via a low-resistance bell circuit) and in hot weather
subscribers would occasionally be asked to go out and water the ground
around the earth spike if they reported that their bell wasn't
ringing.
  #3   Report Post  
Old July 22nd 08, 09:49 PM posted to uk.railway,uk.transport.london
external usenet poster
 
First recorded activity at LondonBanter: Nov 2005
Posts: 4
Default Man electrocuted after urinating on track

Yes Charles...

CBS1 was still around for about 7 years after I
started work. The 'posh' areas around Warrington
were built mainly on sandy soil and both the CBS1
and the CB system party lines, when the latter
weren't fiercely resisted by wealthy and influential
people, were always a problem to maintain in dry weather.

The solution was to do as you described --- or to
pray for rain!


Regards,

DigitisED (Eddie Bellass)

Eddie & Margaret Bellass,
Merseyside, United Kingdom.

Outgoing mail is certified Virus Free and checked
by a leading anti-virus system - updated continuously.



  #4   Report Post  
Old July 24th 08, 07:00 PM posted to uk.railway,uk.transport.london
external usenet poster
 
First recorded activity at LondonBanter: Jul 2003
Posts: 403
Default Man electrocuted after urinating on track

One day I was called to a farm which had reported
their dog howling in distress every time the phone
rang. ...


The farmer had secured his dog with a new steel chain
fastened by an eyebolt to a flat steel bar spiked into the
farmhouse wall. In doing so he had broken the earth
wire for the telephone. ...


In the usual version of this story, the dog barks *before*
the phone rings, because the phone doesn't get enough ringing
current until the urine completes the circuit.

Not that I believe it.
--
Mark Brader, Toronto "I'd opt for Oz, myself."
--Buck Henry
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Man fighting for life after being hit in the head by Tube train in horrific accident at Stockwell station Roland Perry London Transport 12 May 16th 15 06:38 PM
Man avoids prosecution after paying back £43,000-worth of train fares Michael R N Dolbear London Transport 3 April 15th 14 06:25 PM
Track Charts or Track maps of the London Underground [email protected] London Transport 5 December 16th 06 01:30 AM
Claiming a refund after Camden Town derailment Andy Coleman London Transport 11 December 22nd 03 10:50 PM
Minimum speed limit sign after the dartford tunnel? Paul Weaver London Transport 9 September 16th 03 05:25 AM


All times are GMT. The time now is 03:48 AM.

Powered by vBulletin®
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 London Banter.
The comments are property of their posters.
 

About Us

"It's about London Transport"

 

Copyright © 2017